<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Scintillator Detector Archives - X-Z LAB</title>
	<atom:link href="https://www.x-zlab.com/product-category/scintillator-detector/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.x-zlab.com/product-category/scintillator-detector/</link>
	<description>Engineering a Safer World</description>
	<lastBuildDate>Tue, 10 Feb 2026 02:07:23 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>
	<item>
		<title>Plastic &#124; Scintillator Detector</title>
		<link>https://www.x-zlab.com/product/plastic-scintillator-detector-gamma-neutron/</link>
		
		<dc:creator><![CDATA[Lynn Liu]]></dc:creator>
		<pubDate>Fri, 24 Aug 2018 04:17:18 +0000</pubDate>
				<guid isPermaLink="false">https://www.x-zlab.com/?post_type=product&#038;p=3178</guid>

					<description><![CDATA[<p><a class="btn btn-success" style="margin: 10px 0; padding: 15px 25px; font-size: 1.2em;" title="Request quote" href="https://www.x-zlab.com/contact-us/">Request quote</a></p>
<p>The <b data-path-to-node="6" data-index-in-node="4">Plastic Scintillator Detector</b> is a versatile and rugged solution for detecting X-rays, gamma rays, and fast neutrons. It offers superior light transmission and exceptional resistance to vibration and impact. Because it is highly customizable, X-Z LAB provides bespoke detector assemblies in various types and dimensions to meet your specific monitoring needs.</p>
<p>The post <a href="https://www.x-zlab.com/product/plastic-scintillator-detector-gamma-neutron/">Plastic | Scintillator Detector</a> appeared first on <a href="https://www.x-zlab.com">X-Z LAB</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 data-path-to-node="8">Plastic Scintillator Detector | Versatile Radiation Sensing Solutions</h2>
<p data-path-to-node="9">The <b data-path-to-node="9" data-index-in-node="4">Plastic Scintillator Detector</b> is an essential tool for the modern detection of charged particles and high-energy radiation. It is widely used to identify X-rays, gamma rays, and fast neutrons. Consequently, it has become a preferred choice for large-scale security and industrial monitoring. Furthermore, its unique physical properties allow for stable performance even in the most demanding environmental conditions.</p>
<h3 data-path-to-node="10"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6e1.png" alt="🛡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Rugged Durability and Stable Performance</h3>
<p data-path-to-node="11">One of the primary benefits of the <b data-path-to-node="11" data-index-in-node="35">Plastic Scintillator Detector</b> is its high mechanical strength. This material is specifically engineered for vibration and impact resistance. Therefore, it is ideal for mobile detection units or high-traffic industrial zones. Moreover, the scintillator is highly resistant to moisture. This durability ensures that the detector remains reliable in humid or outdoor settings. Because it maintains stable performance under stress, users can trust the data integrity for long-term safety records.</p>
<h3 data-path-to-node="12"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f52c.png" alt="🔬" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Exceptional Optical and Timing Properties</h3>
<p data-path-to-node="13">The efficiency of our <b data-path-to-node="13" data-index-in-node="22">Plastic Scintillator Detector</b> is driven by its superior optical characteristics. It features high transparency and excellent light transmission. This ensures that even small radiation events are captured and recorded. In addition, the detector boasts a very short decay time. This speed is critical for high-rate counting applications where rapid response is mandatory. Consequently, it is a leading choice for passage-way type radioactive detection systems.</p>
<h3 data-path-to-node="14"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f510.png" alt="🔐" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Customizable Sizes and Flexible Applications</h3>
<p data-path-to-node="15">We understand that different monitoring tasks require specific configurations. The <b data-path-to-node="15" data-index-in-node="83">Plastic Scintillator Detector</b> can easily be designed for various types and sizes. For instance, we offer standard dimensions ranging from thin 0.5mm sheets to large 2000mm pillars. Furthermore, X-Z LAB provides complete assembly of plastic scintillation detectors upon request. This flexibility allows you to integrate our technology into isotope gauges, area radiation monitors, and custom security portals with ease.</p>
<h3 data-path-to-node="16">Why Choose Our Plastic Scintillators?</h3>
<p data-path-to-node="17">We focus on delivering high-performance materials that simplify your radiation safety workflow. Because our plastic scintillators combine transparency with mechanical toughness, they provide a cost-effective solution for large-volume detection. Additionally, our ability to customize dimensions ensures that you receive a detector perfectly suited to your facility. It remains the gold standard for professionals who require reliable, large-scale <b data-path-to-node="17" data-index-in-node="447">Plastic Scintillator Detector</b> solutions.</p>
<hr data-path-to-node="18" />
<h2 data-path-to-node="19">Main Applications</h2>
<ul data-path-to-node="20">
<li>
<p data-path-to-node="20,0,0"><b data-path-to-node="20,0,0" data-index-in-node="0">Isotope Gauges:</b> For precise industrial measurement and process control.</p>
</li>
<li>
<p data-path-to-node="20,1,0"><b data-path-to-node="20,1,0" data-index-in-node="0">Passage-way Detection:</b> Ideal for security portals at borders and high-security sites.</p>
</li>
<li>
<p data-path-to-node="20,2,0"><b data-path-to-node="20,2,0" data-index-in-node="0">Area Radiation Monitors:</b> Providing continuous safety oversight for large facilities.</p>
</li>
<li>
<p data-path-to-node="20,3,0"><b data-path-to-node="20,3,0" data-index-in-node="0">Security Screening:</b> Reliable detection of charged particles and radioactive materials.</p>
</li>
</ul>
<hr data-path-to-node="21" />
<h2 data-path-to-node="22">Standard Dimensions (Partial List)</h2>
<table data-path-to-node="23">
<thead>
<tr>
<td><strong>Format</strong></td>
<td><strong>Common Sizes (mm)</strong></td>
</tr>
</thead>
<tbody>
<tr>
<td><span data-path-to-node="23,1,0,0"><b data-path-to-node="23,1,0,0" data-index-in-node="0">Plates</b></span></td>
<td><span data-path-to-node="23,1,1,0">50×500×2000</span></td>
</tr>
<tr>
<td><span data-path-to-node="23,2,0,0"><b data-path-to-node="23,2,0,0" data-index-in-node="0">Blocks</b></span></td>
<td><span data-path-to-node="23,2,1,0">50×50×50</span></td>
</tr>
<tr>
<td><span data-path-to-node="23,3,0,0"><b data-path-to-node="23,3,0,0" data-index-in-node="0">Cylinders</b></span></td>
<td><span data-path-to-node="23,3,1,0">Φ50×2000</span></td>
</tr>
<tr>
<td><span data-path-to-node="23,4,0,0"><b data-path-to-node="23,4,0,0" data-index-in-node="0">Thin Sheets</b></span></td>
<td><span data-path-to-node="23,4,1,0">230×230×0.5</span></td>
</tr>
</tbody>
</table>
<hr data-path-to-node="24" />
<h3 data-path-to-node="25">Technical Specifications Summary</h3>
<table data-path-to-node="26">
<thead>
<tr>
<td><strong>Feature</strong></td>
<td><strong>Specification</strong></td>
</tr>
</thead>
<tbody>
<tr>
<td><span data-path-to-node="26,1,0,0"><b data-path-to-node="26,1,0,0" data-index-in-node="0">Detection Range</b></span></td>
<td><span data-path-to-node="26,1,1,0">X-rays, Gamma rays, Fast Neutrons, Charged Particles</span></td>
</tr>
<tr>
<td><span data-path-to-node="26,2,0,0"><b data-path-to-node="26,2,0,0" data-index-in-node="0">Mechanical Strength</b></span></td>
<td><span data-path-to-node="26,2,1,0">High (Vibration and Impact Resistant)</span></td>
</tr>
<tr>
<td><span data-path-to-node="26,3,0,0"><b data-path-to-node="26,3,0,0" data-index-in-node="0">Response Time</b></span></td>
<td><span data-path-to-node="26,3,1,0">Short Decay Time</span></td>
</tr>
<tr>
<td><span data-path-to-node="26,4,0,0"><b data-path-to-node="26,4,0,0" data-index-in-node="0">Environmental Resistance</b></span></td>
<td><span data-path-to-node="26,4,1,0">Moisture Resistant</span></td>
</tr>
<tr>
<td><span data-path-to-node="26,5,0,0"><b data-path-to-node="26,5,0,0" data-index-in-node="0">Customization</b></span></td>
<td><span data-path-to-node="26,5,1,0">Available upon request (X-Z LAB Assembly)</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.x-zlab.com/product/plastic-scintillator-detector-gamma-neutron/">Plastic | Scintillator Detector</a> appeared first on <a href="https://www.x-zlab.com">X-Z LAB</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>3&#8243;x3&#8243; NaI(Tl) &#124; Scintillator Detector</title>
		<link>https://www.x-zlab.com/product/3x3-nai-tl-scintillator-detector/</link>
		
		<dc:creator><![CDATA[Lynn Liu]]></dc:creator>
		<pubDate>Fri, 24 Aug 2018 04:12:29 +0000</pubDate>
				<guid isPermaLink="false">https://www.x-zlab.com/?post_type=product&#038;p=3176</guid>

					<description><![CDATA[<p><a class="btn btn-success" style="margin: 10px 0; padding: 15px 25px; font-size: 1.2em;" title="Request quote" href="https://www.x-zlab.com/contact-us/">Request quote</a></p>
<p><span class="citation-226">The </span><b data-path-to-node="6" data-index-in-node="4"><span class="citation-226">3"x3" NaI(Tl) Scintillator Detector</span></b><span class="citation-226 citation-end-226"> is a high-resolution, sealed gamma-ray detection unit.</span> <span class="citation-225">Featuring a premium </span><b data-path-to-node="6" data-index-in-node="115"><span class="citation-225">Hamamatsu CR119 photomultiplier tube</span></b><span class="citation-225 citation-end-225"> and a 3-inch sodium iodide crystal, this detector converts radiation into precise electrical pulses.</span> Its rugged aluminum housing makes it an ideal choice for both laboratory spectroscopy and industrial field monitoring.</p>
<p>The post <a href="https://www.x-zlab.com/product/3x3-nai-tl-scintillator-detector/">3&#8243;x3&#8243; NaI(Tl) | Scintillator Detector</a> appeared first on <a href="https://www.x-zlab.com">X-Z LAB</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 data-path-to-node="8">3&#8243;x3&#8243; NaI(Tl) | High-Resolution Scintillator Detector</h2>
<p data-path-to-node="9">The <b data-path-to-node="9" data-index-in-node="4">3&#8243;x3&#8243; NaI(Tl) Scintillator Detector</b> is a meticulously assembled instrument designed for precise gamma-ray measurement. This sealed detector combines high-sensitivity scintillation materials with world-class electronics to capture radiation data with exceptional clarity. Consequently, it has become a standard tool for professionals who require a direct-reading electrical pulse output from radioactive inputs.</p>
<h3 data-path-to-node="10"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6e1.png" alt="🛡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Premium Components for Superior Resolution</h3>
<p data-path-to-node="11">The performance of any <b data-path-to-node="11" data-index-in-node="23">NaI(Tl) Scintillator Detector</b> depends on the quality of its internal components. Our detector is built with a <b data-path-to-node="11" data-index-in-node="133">Dia. 3&#8243;x3&#8243; NaI(Tl) Scintillator</b>, known for its high light yield and excellent energy resolution. This crystal is paired with a <b data-path-to-node="11" data-index-in-node="260">Hamamatsu Dia. <span class="citation-224">3&#8243; CR119 PMT</span></b><span class="citation-224 citation-end-224">, which utilizes an 8-stage structure and a 14-pin connector.</span> Because we use these industry-leading parts, the detector provides stable, high-gain performance even in demanding environments.</p>
<h3 data-path-to-node="12"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f52c.png" alt="🔬" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Rugged Design and Flexible Integration</h3>
<p data-path-to-node="13"><span class="citation-223">The entire assembly is accommodated in a durable </span><b data-path-to-node="13" data-index-in-node="49"><span class="citation-223">aluminum housing</span></b><span class="citation-223 citation-end-223">, providing both physical protection and electromagnetic shielding.</span> This robust design ensures the integrity of the internal vacuum and crystal. <span class="citation-222 citation-end-222">Furthermore, the detector outputs scintillation events directly as electrical pulses.</span> This feature allows for easy connection to multichannel analyzers (like our Tubular Digital MCA) or other data acquisition systems. Therefore, researchers can quickly integrate this detector into their existing spectroscopy pipelines.</p>
<h3 data-path-to-node="14"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f510.png" alt="🔐" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Built for Laboratory and Industrial Safety</h3>
<p data-path-to-node="15">Accuracy and user awareness are critical in radiation monitoring. The <b data-path-to-node="15" data-index-in-node="70">3&#8243;x3&#8243; NaI(Tl) Scintillator Detector</b> focuses on real-world applications where data reliability is paramount. Whether you are performing environmental sampling or medical isotope analysis, this detector delivers consistent results. Additionally, its standardized 3-inch form factor makes it compatible with most lead shielding and collimator systems used in nuclear physics today.</p>
<h3 data-path-to-node="16">Why Choose This NaI(Tl) Detector?</h3>
<p data-path-to-node="17">Designed to maximize the sensitivity of your detection system, this unit focuses on high-resolution gamma-ray spectroscopy. By combining the large-volume 3&#215;3 crystal with a high-performance Hamamatsu PMT, it remains the gold standard for professionals who require a reliable and versatile <b data-path-to-node="17" data-index-in-node="289">NaI(Tl) Scintillator Detector</b>.</p>
<hr data-path-to-node="18" />
<h2 data-path-to-node="19">Key Features</h2>
<ul data-path-to-node="20">
<li>
<p data-path-to-node="20,0,0"><b data-path-to-node="20,0,0" data-index-in-node="0">Scintillator Material:</b> High-resolution Dia. 3&#8243;x3&#8243; NaI(Tl).</p>
</li>
<li>
<p data-path-to-node="20,1,0"><b data-path-to-node="20,1,0" data-index-in-node="0">Photomultiplier Tube (PMT):</b> Hamamatsu CR119 (8-stage, 14-pin).</p>
</li>
<li>
<p data-path-to-node="20,2,0"><b data-path-to-node="20,2,0" data-index-in-node="0">Housing:</b> Lightweight and durable sealed aluminum.</p>
</li>
<li>
<p data-path-to-node="20,3,0"><b data-path-to-node="20,3,0" data-index-in-node="0">Output Type:</b> Direct electrical pulse from scintillation events.</p>
</li>
<li>
<p data-path-to-node="20,4,0"><b data-path-to-node="20,4,0" data-index-in-node="0">Stability:</b> High gain stability for long-term monitoring.</p>
</li>
</ul>
<hr data-path-to-node="21" />
<h3 data-path-to-node="22">Technical Specifications Summary</h3>
<table data-path-to-node="23">
<thead>
<tr>
<td><strong>Feature</strong></td>
<td><strong>Specification</strong></td>
</tr>
</thead>
<tbody>
<tr>
<td><span data-path-to-node="23,1,0,0"><b data-path-to-node="23,1,0,0" data-index-in-node="0">Product Name</b></span></td>
<td><span data-path-to-node="23,1,1,0">3&#8243;x3&#8243; NaI(Tl) Scintillation Detector</span></td>
</tr>
<tr>
<td><span data-path-to-node="23,2,0,0"><b data-path-to-node="23,2,0,0" data-index-in-node="0">Crystal Dimensions</b></span></td>
<td><span data-path-to-node="23,2,1,0">3 inch diameter x 3 inch length</span></td>
</tr>
<tr>
<td><span data-path-to-node="23,3,0,0"><b data-path-to-node="23,3,0,0" data-index-in-node="0">PMT Brand</b></span></td>
<td><span data-path-to-node="23,3,1,0">Hamamatsu</span></td>
</tr>
<tr>
<td><span data-path-to-node="23,4,0,0"><b data-path-to-node="23,4,0,0" data-index-in-node="0">Connector Type</b></span></td>
<td><span data-path-to-node="23,4,1,0">14-pin standard</span></td>
</tr>
<tr>
<td><span data-path-to-node="23,5,0,0"><b data-path-to-node="23,5,0,0" data-index-in-node="0">Housing Material</b></span></td>
<td><span data-path-to-node="23,5,1,0">Aluminum</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.x-zlab.com/product/3x3-nai-tl-scintillator-detector/">3&#8243;x3&#8243; NaI(Tl) | Scintillator Detector</a> appeared first on <a href="https://www.x-zlab.com">X-Z LAB</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>2&#8243;x2&#8243; NaI(Tl) &#124; Scintillator Detector</title>
		<link>https://www.x-zlab.com/product/2x2-nai-tl-scintillator-detector/</link>
		
		<dc:creator><![CDATA[Lynn Liu]]></dc:creator>
		<pubDate>Fri, 24 Aug 2018 04:02:13 +0000</pubDate>
				<guid isPermaLink="false">https://www.x-zlab.com/?post_type=product&#038;p=3175</guid>

					<description><![CDATA[<p><a class="btn btn-success" style="margin: 10px 0; padding: 15px 25px; font-size: 1.2em;" title="Request quote" href="https://www.x-zlab.com/contact-us/">Request quote</a></p>
<p><span class="citation-261">The </span><b data-path-to-node="6" data-index-in-node="4"><span class="citation-261">2"x2" NaI(Tl) Scintillator Detector</span></b><span class="citation-261 citation-end-261"> is a high-resolution, sealed gamma-ray detection system.</span> <span class="citation-260">It integrates a premium </span><b data-path-to-node="6" data-index-in-node="121"><span class="citation-260">Hamamatsu CR105 photomultiplier tube</span></b><span class="citation-260 citation-end-260"> with a 2-inch sodium iodide crystal inside a protective aluminum housing.</span> This compact unit is specifically designed to provide accurate, direct electrical pulse outputs for professional gamma-ray spectroscopy and radiation monitoring.</p>
<p>&#160;</p>
<p>The post <a href="https://www.x-zlab.com/product/2x2-nai-tl-scintillator-detector/">2&#8243;x2&#8243; NaI(Tl) | Scintillator Detector</a> appeared first on <a href="https://www.x-zlab.com">X-Z LAB</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 data-path-to-node="9">2&#8243;x2&#8243; NaI(Tl) | Precision Sealed Scintillator Detector</h2>
<p data-path-to-node="10">The <b data-path-to-node="10" data-index-in-node="4">2&#8243;x2&#8243; NaI(Tl) Scintillator Detector</b> is a high-performance instrument engineered for precise radiation measurement. This assembly combines high-sensitivity scintillation materials with world-class electronics to ensure the highest data integrity. Consequently, it remains a vital tool for specialists who require a reliable interface for gamma-ray detection.</p>
<h3 data-path-to-node="11"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6e1.png" alt="🛡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Optimized Components for High Resolution</h3>
<p data-path-to-node="12">The reliability of a <b data-path-to-node="12" data-index-in-node="21">NaI(Tl) Scintillator Detector</b> depends on the harmony of its internal parts. Our system features a <b data-path-to-node="12" data-index-in-node="119">Dia. 2&#8243;x2&#8243; NaI(Tl) Scintillator</b>, which is prized for its exceptional light yield. This crystal is coupled with a <b data-path-to-node="12" data-index-in-node="232">Hamamatsu Dia. 2&#8243; CR105 PMT</b>.</p>
<p data-path-to-node="13">Moreover, this photomultiplier tube uses a 10-stage structure to deliver superior gain and stability. Because of these high-grade components, the detector maintains consistent performance. It stays stable even during long-term monitoring tasks.</p>
<h3 data-path-to-node="14"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f52c.png" alt="🔬" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Durable Design for Laboratory Integration</h3>
<p data-path-to-node="15">Every detector is accommodated in a sealed <b data-path-to-node="15" data-index-in-node="43">aluminum housing</b>. This provides a rugged shield against physical impact and light interference. This robust structure also protects the sensitive internal vacuum.</p>
<p data-path-to-node="16">Furthermore, the detector outputs scintillation events directly as electrical pulses. This capability allows for seamless integration with multichannel analyzers. Therefore, it is highly compatible with existing laboratory setups and field monitoring systems.</p>
<h3 data-path-to-node="17"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f510.png" alt="🔐" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Built for Multi-Sector Radiation Safety</h3>
<p data-path-to-node="18">Professional awareness and accuracy are the core values of our detection line. The <b data-path-to-node="18" data-index-in-node="83">2&#8243;x2&#8243; NaI(Tl) Scintillator Detector</b> is widely utilized in sectors where precision is mandatory. For instance, it is ideal for environmental protection and medical health.</p>
<p data-path-to-node="19">In addition, the nuclear industry uses this detector for isotopic identification. Its compact 2-inch form factor allows for easy installation in lead shields. It also fits perfectly into portable detection rigs.</p>
<h3 data-path-to-node="20">Why Choose the 2&#215;2 NaI(Tl) Detector?</h3>
<p data-path-to-node="21">We designed this unit to maximize the efficiency of your spectroscopy workflow. It focuses on high-resolution performance in a compact frame. By pairing the 2&#215;2 crystal with a 10-stage Hamamatsu PMT, it remains a premier <b data-path-to-node="21" data-index-in-node="221">NaI(Tl) Scintillator Detector</b>. It is the top choice for researchers who demand repeatable results.</p>
<hr data-path-to-node="22" />
<h2 data-path-to-node="23">Key Features</h2>
<ul data-path-to-node="24">
<li>
<p data-path-to-node="24,0,0"><b data-path-to-node="24,0,0" data-index-in-node="0">Scintillator Material:</b> High-resolution Dia. 2&#8243;x2&#8243; NaI(Tl).</p>
</li>
<li>
<p data-path-to-node="24,1,0"><b data-path-to-node="24,1,0" data-index-in-node="0">Photomultiplier Tube (PMT):</b> Hamamatsu CR105 (10-stage, 14-pin).</p>
</li>
<li>
<p data-path-to-node="24,2,0"><b data-path-to-node="24,2,0" data-index-in-node="0">Sealed Housing:</b> Lightweight and durable aluminum.</p>
</li>
<li>
<p data-path-to-node="24,3,0"><b data-path-to-node="24,3,0" data-index-in-node="0">Output Efficiency:</b> Direct electrical pulse output.</p>
</li>
<li>
<p data-path-to-node="24,4,0"><b data-path-to-node="24,4,0" data-index-in-node="0">Versatile Fit:</b> Standard 2-inch diameter.</p>
</li>
</ul>
<hr data-path-to-node="25" />
<h3 data-path-to-node="26">Technical Specifications Summary</h3>
<table data-path-to-node="27">
<thead>
<tr>
<td><strong>Feature</strong></td>
<td><strong>Specification</strong></td>
</tr>
</thead>
<tbody>
<tr>
<td><span data-path-to-node="27,1,0,0"><b data-path-to-node="27,1,0,0" data-index-in-node="0">Product Name</b></span></td>
<td><span data-path-to-node="27,1,1,0">2&#8243;x2&#8243; NaI(Tl) Scintillation Detector</span></td>
</tr>
<tr>
<td><span data-path-to-node="27,2,0,0"><b data-path-to-node="27,2,0,0" data-index-in-node="0">Crystal Dimensions</b></span></td>
<td><span data-path-to-node="27,2,1,0">2 inch diameter x 2 inch length</span></td>
</tr>
<tr>
<td><span data-path-to-node="27,3,0,0"><b data-path-to-node="27,3,0,0" data-index-in-node="0">PMT Brand</b></span></td>
<td><span data-path-to-node="27,3,1,0">Hamamatsu (CR105)</span></td>
</tr>
<tr>
<td><span data-path-to-node="27,4,0,0"><b data-path-to-node="27,4,0,0" data-index-in-node="0">Connector Type</b></span></td>
<td><span data-path-to-node="27,4,1,0">14-pin standard</span></td>
</tr>
<tr>
<td><span data-path-to-node="27,5,0,0"><b data-path-to-node="27,5,0,0" data-index-in-node="0">Housing Material</b></span></td>
<td><span data-path-to-node="27,5,1,0">Aluminum</span></td>
</tr>
</tbody>
</table>
<h2 data-path-to-node="8"></h2>
<p>The post <a href="https://www.x-zlab.com/product/2x2-nai-tl-scintillator-detector/">2&#8243;x2&#8243; NaI(Tl) | Scintillator Detector</a> appeared first on <a href="https://www.x-zlab.com">X-Z LAB</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LaBr3(Ce) &#124; Scintillator Detector</title>
		<link>https://www.x-zlab.com/product/labr3-detector/</link>
		
		<dc:creator><![CDATA[Lynn Liu]]></dc:creator>
		<pubDate>Fri, 24 Aug 2018 03:47:12 +0000</pubDate>
				<guid isPermaLink="false">https://www.x-zlab.com/?post_type=product&#038;p=3172</guid>

					<description><![CDATA[<p><a class="btn btn-success" style="margin: 10px 0; padding: 15px 25px; font-size: 1.2em;" title="Request quote" href="https://www.x-zlab.com/contact-us/">Request quote</a></p>
<p>LaBr3(Ce) &#124; Scintillator Detector uses direct coupling between LaBr3 crystal and PMT, improving the time and energy efficiency.</p>
<p>The post <a href="https://www.x-zlab.com/product/labr3-detector/">LaBr3(Ce) | Scintillator Detector</a> appeared first on <a href="https://www.x-zlab.com">X-Z LAB</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>LaBr3(Ce) | Scintillator Detector utilizes LaBr3 crystal and PMT directly coupling. No optical window is needed between the crystal and PMT, improving the detection efficiency, as well as high energy resolution, time resolution, good energy nonlinearity, and fast decay time. It is widely used in the radiation detection field, energy spectrometer detectors, and high-temperature oil well logging detectors.</p>
<p>&nbsp;</p>
<p><strong>MAIN APPLICATIONS</strong></p>
<ul>
<li>Environmental monitoring</li>
<li>Oil well logging</li>
<li>Nuclear medicine</li>
<li>Nuclear medicine security</li>
<li>Counterterrorism</li>
<li>Nuclide identification</li>
</ul>
<p>The post <a href="https://www.x-zlab.com/product/labr3-detector/">LaBr3(Ce) | Scintillator Detector</a> appeared first on <a href="https://www.x-zlab.com">X-Z LAB</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CZT &#124; Scintillator Detector</title>
		<link>https://www.x-zlab.com/product/czt-detector/</link>
		
		<dc:creator><![CDATA[Lynn Liu]]></dc:creator>
		<pubDate>Fri, 24 Aug 2018 03:27:34 +0000</pubDate>
				<guid isPermaLink="false">https://www.x-zlab.com/?post_type=product&#038;p=3170</guid>

					<description><![CDATA[<div><a class="btn btn-success" style="margin: 10px 0; padding: 15px 25px; font-size: 1.2em;" title="Request quote" href="https://www.x-zlab.com/contact-us/">Request quote</a></div>
<div></div>
<div>The CZT &#124; Scintillator Detector semiconductor is a pixilated array in which gamma rays enter and are directly converted into electron hole pairs, inducing electrical output signals.</div>
<p>The post <a href="https://www.x-zlab.com/product/czt-detector/">CZT | Scintillator Detector</a> appeared first on <a href="https://www.x-zlab.com">X-Z LAB</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The CZT | Scintillator Detector is a pixilated semiconductor array with an effective Z of 50 and a density of 5.8 g/cm3. Gamma rays enter the CZT semiconductor detector and are directly converted to electron hole pairs. These charges (electrons and holes) then drift towards positive and negative electrodes, respectively, inducing electrical output signals. Area array and linear array detectors are also available.</p>
<p>&nbsp;</p>
<p><strong>MAIN APPLICATIONS</strong></p>
<ul>
<li>Medicine application</li>
<li>Homeland security</li>
<li>Industrial process control</li>
<li>Food inspection</li>
</ul>
<p>The post <a href="https://www.x-zlab.com/product/czt-detector/">CZT | Scintillator Detector</a> appeared first on <a href="https://www.x-zlab.com">X-Z LAB</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CsI(Tl) &#124; Scintillator Detector</title>
		<link>https://www.x-zlab.com/product/csitl-detector/</link>
		
		<dc:creator><![CDATA[Lynn Liu]]></dc:creator>
		<pubDate>Mon, 20 Aug 2018 21:38:49 +0000</pubDate>
				<guid isPermaLink="false">https://www.x-zlab.com/?post_type=product&#038;p=3157</guid>

					<description><![CDATA[<p><a class="btn btn-success" title="Request quote" href="https://www.x-zlab.com/contact-us/">Request quote</a></p>
<p>CsI(Tl) &#124; Scintillator Detector is a linear photodiode array which is widely used in security applications and is customizable upon request.</p>
<p>The post <a href="https://www.x-zlab.com/product/csitl-detector/">CsI(Tl) | Scintillator Detector</a> appeared first on <a href="https://www.x-zlab.com">X-Z LAB</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>CsI(Tl) | Scintillator Detector is a linear photodiode array which is widely used in security applications such as luggage scanning, cargo/container screening, food inspection, non-destructive testing, industrial inspection, and more. We can customize linear photodiode arrays for X-ray scanning, with high energy resolution and high imaging quality according to your request.</p>
<p>&nbsp;</p>
<p><strong>MAIN APPLICATIONS</strong></p>
<ul>
<li>Luggage scanning</li>
<li>Cargo/container screening</li>
<li>Food inspection</li>
<li>Non- destructive testing</li>
<li>Industrial inspection</li>
</ul>
<p>The post <a href="https://www.x-zlab.com/product/csitl-detector/">CsI(Tl) | Scintillator Detector</a> appeared first on <a href="https://www.x-zlab.com">X-Z LAB</a>.</p>